@co8986

SSA makes Autocad civil 3d more interesting,Thank you for your presentation.

@johnsayre4827

Yes. The Pipe size will update when you import back in the pipe networks. You can either have Civil 3D create a new network or update the existing networks.
John

@RG_noBS

what a great video. Thanks Sir!!

@AutoCADRevitByju

Good information, do you created any Technology based Civil 3d video, Like Electrical power cabinet, Electrical Duct & 3D asset tagging. Please upload if you have , thanks @john Sayre

@masoodalikhan9870

Should we design sewer and storm drainage separately or jointly using SSA and hydraflow?

@ntuthuko3175

Hello.

Thank you for your videos. Please help with these two questions.

1. Some of my structures disappear from Civil3D after importing and updating the network from SSA. All of my structures are the same. In addition, one of my pipes flips over thus disconnecting from its outlet structure. What could cause this?

2. Is there a way of bringing the peak flow values into Civil3D in order to show them in the profile labeling?

Thank you.

@e.m.1979

Hi, the file .stm that I have imported to civil 3D is update. But all pipe, elevation, dimension, etc, did not change in profile and plan. What to do to fix it? Thanks

@oscarniltonquirozgamboa2025

hello, you can make a tutorial of making hydraulic calculations in storm sanitary of a sanitary sewer network

@dylanb3957

John I hope this comment reaches you. I've run a storm model and it says some of my pipes are surcharged when my HGL is low. How can this be?

@emmanueladewumi8651

Hi John, 

Please how did you get your external flow to be 3 CFS? Did you get it from the run-off discharge?  Which rainfall return period did you use? Thank you.

@johnsayre4827

Not that I know of. Do you have all of the service packs applied?

@techmindsglobalintegrated4842

nice video, but i have a question  what is the structure style used by these junction structures?

@johnsayre4827

Hey Elton. What changes did you make in SSA that should have come through?

@e.m.1979

I changed the dimensions of pipe and elevation of pipe (slope) and junctions because the pipe are very small. I tried on civil 3D 2012 and everything is ok. On civil 3D 2013 no. Is any problem with 2013?

@e.m.1979

I do not know, how to find it if I have all service packs. Thank you ......

@prabhatjoshi2915

Sir, is this a continuation of some video lecture or tutorial series?

@agurod-k7p

Great video!
i have a question: can storm and sanitary analysis automatically update the pipe size?
if the system is big (>200 pipes or so) and half needs to be updated, is going to be time consuming to manually increase the pipe size.
Thank you again for the video

@abuomeribrahim7220

can  you submit the drawing for practicing?

@ralphaaron1

Thank you so much for this video, it is very helpful !

@johnsayre4827

My Civil 3D is up to date and my product version is 10.5.965.0. It also says SP2.0